The pH PLUS Family of compact,modular pH Neutralization Systems are perfect for continuous flows up to 50 GPM. They provide simple, reliable compliance in one compact, affordable module. Ideal for labs, hospitals, institutions and light industrial waste streams. Designed for continuous use, they can easily be adapted to work in batch mode. Choose the pH PLUS, PHX model to meet your requirements.
|
 |
 |
|
 |
 |
|
 |
All PHX models incorporate Burt Process Equipment's proprietary (AVS) mix tank for optimal agitation with a minimal use of floor space.
Each PHX module is shipped completely assembled ready for connection to inlet,drain, vent and power. Simple reagent replenishment and periodic instrumentation calibration is all the maintenance that is required.
|
|
 |
|
 |
|
| Component Materials and Specifications: |
|
|
 |
 |
|
 |
 |
 |
Treatment Tank/Shell |
 |
Heavy Duty Reinforced Polypropylene |
 |
 |
 |
Reagent Vessels |
 |
FRP wrapped polyethylene
Piping: PVC, CPVC, Polypropylene |
 |
 |
 |
Metering Pumps |
 |
Variable Speed Electronic Solenoid, Analog Input, Polypropylene Level Controls: Magnetic Reed, CPVC/Polypropylene |
 |
 |
 |
Mixers |
 |
Low Speed, High Efficiency, Extended Life Bearings, 304 SS Low Sheer Prop |
 |
 |
|
|
|
|
 |
|
|
 |
|
| Options and Accessories |
|
|
 |
 |
|
 |
 |
Pre-Treatment Chemical Feed |
 |
Influent/Effluent Pump Transfer Stations |
 |
Automatic or Manual Effluent Samplers |
 |
High Temperature Materials |
 |
HMI/SCADA Interface |
 |
Touch Screen Monitoring and Control |
 |
Chemical Transfer Pump Systems |
 |
Effluent Flow Monitors |
 |
Secondary Containment Systems |
|
|
 |
|
| System Performance and Specifications |
|
|
 |
 |
|
 |
pH PLUS Continuous Flow and Batch Treatment Modules
 |
 |
MODEL |
 |
PHX-100 |
 |
PHX-200 |
 |
PHX-300 |
 |
PHX-400 |
 |
PHX-500 |
 |
 |
 |
Continuous Flow Capacity
(Nominal GPM) |
 |
10 |
 |
20 |
 |
30 |
 |
40 |
 |
50 |
 |
 |
 |
Mix Tank Volume (Gal.) |
 |
100 |
 |
200 |
 |
300 |
 |
400 |
 |
500 |
 |
 |
 |
Reagent Tanks Volume (Gal.) |
 |
20 |
 |
20 |
 |
20 |
 |
30 |
 |
30 |
 |
 |
 |
Reagent Pumps Capacity |
 |
5.0 |
 |
5.0 |
 |
5.0 |
 |
10.0 |
 |
10.0 |
 |
 |
 |
Reaction Mixer (HP) |
 |
0.25 |
 |
0.25 |
 |
0.25 |
 |
0.25 |
 |
0.25 |
 |
 |
 |
Dimensions
(ft.-in.) |
Length A |
| Width B |
| Height C |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
 |
 |
Electrical Power (Amps) |
 |
12.0 |
 |
12.0 |
 |
12.0 |
 |
12.0 |
 |
12.0 |
 |
 |
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
 |
*Specify suffix-EM for effluent pH monitor and 31-day strip chart recorder. Example:Model PHX-200-EM |
|
|
|
|
 |
|
|
|
 |
|
|
|
 |
|
|
|
|